{"containers":{"cna":{"affected":[{"product":"IIoT Monitor 3.1.38","vendor":"Schneider Electric SE","versions":[{"status":"affected","version":"IIoT Monitor 3.1.38"}]}],"datePublic":"2018-12-24T00:00:00.000Z","descriptions":[{"lang":"en","value":"An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in IIoT Monitor 3.1.38 which could allow access to files available to SYSTEM user."}],"problemTypes":[{"descriptions":[{"description":"Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2019-01-10T10:57:01.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"name":"106484","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/106484"},{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7835","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"IIoT Monitor 3.1.38","version":{"version_data":[{"version_value":"IIoT Monitor 3.1.38"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in IIoT Monitor 3.1.38 which could allow access to files available to SYSTEM user."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"}]}]},"references":{"reference_data":[{"name":"106484","refsource":"BID","url":"http://www.securityfocus.com/bid/106484"},{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T06:37:59.606Z"},"title":"CVE Program Container","references":[{"name":"106484","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/106484"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/"}]}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2018-7835","datePublished":"2018-12-24T16:00:00.000Z","dateReserved":"2018-03-08T00:00:00.000Z","dateUpdated":"2024-08-05T06:37:59.606Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}