{"containers":{"cna":{"affected":[{"product":"Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)","vendor":"Schneider","versions":[{"status":"affected","version":"Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"},{"status":"affected","version":"For 32-bit Windows OS:V2.17 IE 27 and prior"},{"status":"affected","version":"and as part of the Driver Suite version:V14.12 and prior)"}]}],"datePublic":"2019-04-09T00:00:00.000Z","descriptions":[{"lang":"en","value":"An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-610","description":"Externally Controlled Reference to a Resource (CWE-610)","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-05-22T19:27:44.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7824","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)","version":{"version_data":[{"version_value":"Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"},{"version_value":"For 32-bit Windows OS:V2.17 IE 27 and prior"},{"version_value":"and as part of the Driver Suite version:V14.12 and prior)"}]}}]},"vendor_name":"Schneider"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Externally Controlled Reference to a Resource (CWE-610)"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T06:37:59.163Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"}]}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2018-7824","datePublished":"2019-05-22T19:27:44.000Z","dateReserved":"2018-03-08T00:00:00.000Z","dateUpdated":"2024-08-05T06:37:59.163Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}