{"containers":{"cna":{"affected":[{"product":"Zelio Soft 2 v5.1 and prior versions","vendor":"Schneider Electric SE","versions":[{"status":"affected","version":"Zelio Soft 2 v5.1 and prior versions"}]}],"datePublic":"2019-02-06T00:00:00.000Z","descriptions":[{"lang":"en","value":"A Use After Free (CWE-416) vulnerability exists in Zelio Soft 2 v5.1 and prior versions which could cause remote code execution when opening a specially crafted Zelio Soft project file."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-416","description":"Use After Free (CWE-416)","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-04-03T14:28:58.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"name":"106481","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/106481"},{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-361-01/"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7817","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Zelio Soft 2 v5.1 and prior versions","version":{"version_data":[{"version_value":"Zelio Soft 2 v5.1 and prior versions"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Use After Free (CWE-416) vulnerability exists in Zelio Soft 2 v5.1 and prior versions which could cause remote code execution when opening a specially crafted Zelio Soft project file."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Use After Free (CWE-416)"}]}]},"references":{"reference_data":[{"name":"106481","refsource":"BID","url":"http://www.securityfocus.com/bid/106481"},{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-361-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-361-01/"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-01"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T06:37:59.360Z"},"title":"CVE Program Container","references":[{"name":"106481","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/106481"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-361-01/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-008-01"}]}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2018-7817","datePublished":"2019-02-06T23:00:00.000Z","dateReserved":"2018-03-08T00:00:00.000Z","dateUpdated":"2024-08-05T06:37:59.360Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}