{"containers":{"cna":{"affected":[{"product":"Modicon M221, All Versions","vendor":"Schneider Electric SE","versions":[{"status":"affected","version":"Modicon M221, All Versions"}]}],"datePublic":"2018-11-02T00:00:00.000Z","descriptions":[{"lang":"en","value":"A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device."}],"problemTypes":[{"descriptions":[{"description":"Insufficient Verification of Data Authenticity","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-11-21T10:57:01.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","shortName":"schneider"},"references":[{"name":"105970","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/105970"},{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7798","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Modicon M221, All Versions","version":{"version_data":[{"version_value":"Modicon M221, All Versions"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Insufficient Verification of Data Authenticity"}]}]},"references":{"reference_data":[{"name":"105970","refsource":"BID","url":"http://www.securityfocus.com/bid/105970"},{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T06:37:59.359Z"},"title":"CVE Program Container","references":[{"name":"105970","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/105970"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/"}]},{"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-345","lang":"en","description":"CWE-345 Insufficient Verification of Data Authenticity"}]}],"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":8.2,"attackVector":"NETWORK","baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"LOW","privilegesRequired":"NONE","confidentialityImpact":"NONE"}},{"other":{"type":"ssvc","content":{"timestamp":"2026-05-29T14:08:28.530951Z","id":"CVE-2018-7798","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-05-29T14:09:12.112Z"}}]},"cveMetadata":{"assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","assignerShortName":"schneider","cveId":"CVE-2018-7798","datePublished":"2018-11-02T17:00:00.000Z","dateReserved":"2018-03-08T00:00:00.000Z","dateUpdated":"2026-05-29T14:09:12.112Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.2"}