{"containers":{"cna":{"affected":[{"product":"Triconex Tricon","vendor":"Schneider Electric","versions":[{"status":"affected","version":"MP model 3008 firmware versions 10.0-10.4"}]}],"datePublic":"2018-04-17T00:00:00.000Z","descriptions":[{"lang":"en","value":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-119","description":"Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2018-05-05T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"},{"name":"103947","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/103947"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2018-04-17T00:00:00","ID":"CVE-2018-7522","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Triconex Tricon","version":{"version_data":[{"version_value":"MP model 3008 firmware versions 10.0-10.4"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"},{"name":"103947","refsource":"BID","url":"http://www.securityfocus.com/bid/103947"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T06:31:04.336Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"},{"name":"103947","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/103947"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2018-7522","datePublished":"2018-05-04T17:00:00.000Z","dateReserved":"2018-02-26T00:00:00.000Z","dateUpdated":"2024-09-17T00:02:25.672Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}