{"containers":{"cna":{"affected":[{"product":"DIGSI 4","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.92"}]},{"product":"EN100 Ethernet module DNP3 variant","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V1.05.00"}]},{"product":"EN100 Ethernet module IEC 104 variant","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"EN100 Ethernet module IEC 61850 variant","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.30"}]},{"product":"EN100 Ethernet module Modbus TCP variant","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"EN100 Ethernet module PROFINET IO variant","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"Other SIPROTEC 4 relays","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"Other SIPROTEC Compact relays","vendor":"Siemens","versions":[{"status":"affected","version":"All versions"}]},{"product":"SIPROTEC 4 7SD80","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.70"}]},{"product":"SIPROTEC 4 7SJ61","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.96"}]},{"product":"SIPROTEC 4 7SJ62","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.96"}]},{"product":"SIPROTEC 4 7SJ64","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.96"}]},{"product":"SIPROTEC 4 7SJ66","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.30"}]},{"product":"SIPROTEC Compact 7SJ80","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.77"}]},{"product":"SIPROTEC Compact 7SK80","vendor":"Siemens","versions":[{"status":"affected","version":"All versions < V4.77"}]}],"datePublic":"2018-03-08T00:00:00.000Z","descriptions":[{"lang":"en","value":"A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-326","description":"CWE-326: Inadequate Encryption Strength","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2021-07-13T11:02:46.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2018-4839","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"DIGSI 4","version":{"version_data":[{"version_value":"All versions < V4.92"}]}},{"product_name":"EN100 Ethernet module DNP3 variant","version":{"version_data":[{"version_value":"All versions < V1.05.00"}]}},{"product_name":"EN100 Ethernet module IEC 104 variant","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"EN100 Ethernet module IEC 61850 variant","version":{"version_data":[{"version_value":"All versions < V4.30"}]}},{"product_name":"EN100 Ethernet module Modbus TCP variant","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"EN100 Ethernet module PROFINET IO variant","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"Other SIPROTEC 4 relays","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"Other SIPROTEC Compact relays","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SIPROTEC 4 7SD80","version":{"version_data":[{"version_value":"All versions < V4.70"}]}},{"product_name":"SIPROTEC 4 7SJ61","version":{"version_data":[{"version_value":"All versions < V4.96"}]}},{"product_name":"SIPROTEC 4 7SJ62","version":{"version_data":[{"version_value":"All versions < V4.96"}]}},{"product_name":"SIPROTEC 4 7SJ64","version":{"version_data":[{"version_value":"All versions < V4.96"}]}},{"product_name":"SIPROTEC 4 7SJ66","version":{"version_data":[{"version_value":"All versions < V4.30"}]}},{"product_name":"SIPROTEC Compact 7SJ80","version":{"version_data":[{"version_value":"All versions < V4.77"}]}},{"product_name":"SIPROTEC Compact 7SK80","version":{"version_data":[{"version_value":"All versions < V4.77"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-326: Inadequate Encryption Strength"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T05:18:26.659Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2018-4839","datePublished":"2018-03-08T17:00:00.000Z","dateReserved":"2018-01-02T00:00:00.000Z","dateUpdated":"2024-08-05T05:18:26.659Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}