{"containers":{"cna":{"affected":[{"product":"ROX II","vendor":"Siemens AG","versions":[{"status":"affected","version":"All versions < V2.12.1"}]}],"datePublic":"2018-10-09T00:00:00.000Z","descriptions":[{"lang":"en","value":"A vulnerability has been identified in ROX II (All versions < V2.12.1). An attacker with network access to port 22/tcp and valid low-privileged user credentials for the target device could perform a privilege escalation and gain root privileges. Successful exploitation requires user privileges of a low-privileged user but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-264","description":"CWE-264: Permissions, Privileges, and Access Controls","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2018-10-12T09:57:01.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf"},{"name":"105545","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/105545"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","DATE_PUBLIC":"2018-10-09T00:00:00","ID":"CVE-2018-13801","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"ROX II","version":{"version_data":[{"version_value":"All versions < V2.12.1"}]}}]},"vendor_name":"Siemens AG"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in ROX II (All versions < V2.12.1). An attacker with network access to port 22/tcp and valid low-privileged user credentials for the target device could perform a privilege escalation and gain root privileges. Successful exploitation requires user privileges of a low-privileged user but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-264: Permissions, Privileges, and Access Controls"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf"},{"name":"105545","refsource":"BID","url":"http://www.securityfocus.com/bid/105545"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T09:14:47.229Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf"},{"name":"105545","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/105545"}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2018-13801","datePublished":"2018-10-10T17:00:00.000Z","dateReserved":"2018-07-10T00:00:00.000Z","dateUpdated":"2024-09-16T22:10:15.826Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}