{"containers":{"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2017-08-05T00:00:00.000Z","descriptions":[{"lang":"en","value":"An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected"}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2017-08-21T08:57:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"tags":["x_refsource_MISC"],"url":"http://www.sma.de/en/statement-on-cyber-security.html"},{"tags":["x_refsource_MISC"],"url":"https://horusscenario.com/CVE-information/"},{"tags":["x_refsource_MISC"],"url":"http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf"}],"tags":["disputed"],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2017-9855","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"** DISPUTED ** An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.sma.de/en/statement-on-cyber-security.html","refsource":"MISC","url":"http://www.sma.de/en/statement-on-cyber-security.html"},{"name":"https://horusscenario.com/CVE-information/","refsource":"MISC","url":"https://horusscenario.com/CVE-information/"},{"name":"http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf","refsource":"MISC","url":"http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf"}]}}},"adp":[{"problemTypes":[{"descriptions":[{"type":"CWE","cweId":"CWE-863","lang":"en","description":"CWE-863 Incorrect Authorization"}]}],"affected":[{"vendor":"sma","product":"sunny_boy_3600_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_3600_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_5000_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_5000_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_tripower_core1_firmware","cpes":["cpe:2.3:o:sma:sunny_tripower_core1_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_tripower_15000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_tripower_15000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_tripower_20000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_tripower_20000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_tripower_25000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_tripower_25000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_tripower_5000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_tripower_5000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_tripower_12000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_tripower_12000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_tripower_60_firmware","cpes":["cpe:2.3:o:sma:sunny_tripower_60_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_3000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_3000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_3600tl_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_3600tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_4000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_4000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_5000tl_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_5000tl_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_1.5_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_1.5_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_2.5_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_2.5_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_3.0_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_3.0_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_3.6_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_3.6_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_4.0_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_4.0_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_5.0_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_5.0_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_2200_firmware","cpes":["cpe:2.3:o:sma:sunny_central_2200_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_1000cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_1000cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_800cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_800cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_850cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_850cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_900cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_900cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_500cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_500cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_630cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_630cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_720cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_720cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_760cp_xt_firmware","cpes":["cpe:2.3:o:sma:sunny_central_760cp_xt_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_500_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_500_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_630_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_630_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_720_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_720_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_760_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_760_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_800_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_800_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_850_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_850_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_900_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_900_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_1000_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_1000_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_2200_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_2200_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_central_storage_2500-ev_firmware","cpes":["cpe:2.3:o:sma:sunny_central_storage_2500-ev_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]},{"vendor":"sma","product":"sunny_boy_storage_2.5_firmware","cpes":["cpe:2.3:o:sma:sunny_boy_storage_2.5_firmware:-:*:*:*:*:*:*:*"],"defaultStatus":"unknown","versions":[{"version":"-","status":"affected"}]}],"metrics":[{"cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":9.8,"attackVector":"NETWORK","baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"HIGH"}},{"other":{"type":"ssvc","content":{"timestamp":"2024-04-23T16:01:09.712724Z","id":"CVE-2017-9855","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-10-29T13:57:15.277Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T17:18:02.233Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.sma.de/en/statement-on-cyber-security.html"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://horusscenario.com/CVE-information/"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf"}]}]},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2017-9855","datePublished":"2017-08-05T17:00:00.000Z","dateReserved":"2017-06-24T00:00:00.000Z","dateUpdated":"2024-10-29T13:57:15.277Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}