{"containers":{"cna":{"affected":[{"defaultStatus":"unaffected","product":"QNX Software Development Platform (SDP)","vendor":"BlackBerry","versions":[{"status":"affected","version":"6.6.0"},{"status":"affected","version":"6.5.0 SP1 and earlier"}]}],"datePublic":"2017-11-14T05:00:00.000Z","descriptions":[{"lang":"en","supportingMedia":[{"base64":false,"type":"text/html","value":"<p>In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.</p>"}],"value":"In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."}],"impacts":[{"capecId":"CAPEC-13","descriptions":[{"lang":"en","value":"CAPEC-13 Subverting Environment Variable Values"}]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":3.8,"baseSeverity":"LOW","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N","version":"3.1"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-200","description":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor","lang":"en","type":"CWE"}]}],"providerMetadata":{"orgId":"dbe78b00-5e7b-4fda-8748-329789ecfc5c","shortName":"blackberry","dateUpdated":"2025-08-26T17:30:03.762Z"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"}],"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.2.0"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"secure@blackberry.com","DATE_PUBLIC":"2017-11-14T00:00:00","ID":"CVE-2017-9369","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"QNX Software Development Platform (QNX SDP)","version":{"version_data":[{"version_value":"6.6.0"},{"version_value":"6.5.0 SP1 and earlier"}]}}]},"vendor_name":"BlackBerry"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Information disclosure across privilege barriers."}]}]},"references":{"reference_data":[{"name":"http://support.blackberry.com/kb/articleDetail?articleNumber=000046674","refsource":"CONFIRM","url":"http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T17:02:44.381Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"}]}]},"cveMetadata":{"assignerOrgId":"dbe78b00-5e7b-4fda-8748-329789ecfc5c","assignerShortName":"blackberry","cveId":"CVE-2017-9369","datePublished":"2017-11-14T21:00:00.000Z","dateReserved":"2017-06-02T00:00:00.000Z","dateUpdated":"2025-08-26T17:30:03.762Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}