{"containers":{"cna":{"affected":[{"product":"Schneider Electric Modicon M340 PLC","vendor":"n/a","versions":[{"status":"affected","version":"Schneider Electric Modicon M340 PLC"}]}],"datePublic":"2017-06-29T00:00:00.000Z","descriptions":[{"lang":"en","value":"A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover."}],"problemTypes":[{"descriptions":[{"cweId":"CWE-400","description":"CWE-400","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2018-12-24T15:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_CONFIRM"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"},{"name":"96414","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/96414"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-6017","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Schneider Electric Modicon M340 PLC","version":{"version_data":[{"version_value":"Schneider Electric Modicon M340 PLC"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-400"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"},{"name":"96414","refsource":"BID","url":"http://www.securityfocus.com/bid/96414"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T15:18:49.611Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"},{"name":"96414","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/96414"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2017-6017","datePublished":"2017-06-30T02:35:00.000Z","dateReserved":"2017-02-16T00:00:00.000Z","dateUpdated":"2024-08-05T15:18:49.611Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}