{"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-09-10T09:33:18.492Z"},"descriptions":[{"lang":"en","value":"Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."}],"affected":[{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","versions":[{"status":"affected","version":"All versions < V4.1.1 Patch04"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200","versions":[{"status":"affected","version":"All versions < V4.2.1 Patch03"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P","versions":[{"status":"affected","version":"All versions < V4.4.0 Patch01"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Extension Unit 12\" PROFINET","versions":[{"status":"affected","version":"All versions < V01.01.01"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Extension Unit 15\" PROFINET","versions":[{"status":"affected","version":"All versions < V01.01.01"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Extension Unit 19\" PROFINET","versions":[{"status":"affected","version":"All versions < V01.01.01"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Extension Unit 22\" PROFINET","versions":[{"status":"affected","version":"All versions < V01.01.01"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"IE/AS-i Link PN IO","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"IE/PB-Link (incl. SIPLUS NET variants)","versions":[{"status":"affected","version":"All versions < V3.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)","versions":[{"status":"affected","version":"All versions < V4.03"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE W-700 IEEE 802.11n family","versions":[{"status":"affected","version":"All versions < V6.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X-200 family (incl. SIPLUS NET variants)","versions":[{"status":"affected","version":"All versions < V5.2.2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X-200IRT family (incl. SIPLUS NET variants)","versions":[{"status":"affected","version":"All versions < V5.4.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)","versions":[{"status":"affected","version":"All versions < V4.1.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X408 family","versions":[{"status":"affected","version":"All versions < V4.1.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE X414","versions":[{"status":"affected","version":"All versions < V3.10.2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XM-400 family","versions":[{"status":"affected","version":"All versions < V6.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XR-500 family","versions":[{"status":"affected","version":"All versions < V6.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CM 1542-1","versions":[{"status":"affected","version":"All versions < V2.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CM 1542SP-1","versions":[{"status":"affected","version":"All versions < V1.0.15"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.1.82"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.1.82"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1243-7 LTE US","versions":[{"status":"affected","version":"All versions < V2.1.82"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1243-8 IRC","versions":[{"status":"affected","version":"All versions < V2.1.82"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1243-8 IRC","versions":[{"status":"affected","version":"All versions < V2.1.82"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V1.0.15"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1543-1 (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1543SP-1 (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V1.0.15"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1604","versions":[{"status":"affected","version":"All versions < V2.7"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1616","versions":[{"status":"affected","version":"All versions < V2.7"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 1626","versions":[{"status":"affected","version":"All versions < V1.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 343-1 (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V3.1.3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 343-1 Lean (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V3.1.3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 443-1 (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V3.2.17"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V3.2.17"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC CP 443-1 OPC UA","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC DK-16xx PN IO","versions":[{"status":"affected","version":"All versions < V2.7"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200AL IM 157-1 PN","versions":[{"status":"affected","version":"0","lessThan":"V1.0.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200M (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN BA","versions":[{"status":"affected","version":"0","lessThan":"V4.0.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN ST","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-3 PN HF","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-4 PN HF","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN BA","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HS","versions":[{"status":"affected","version":"0","lessThan":"V4.0.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST BA","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 4AO U/I 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN: IO-Link Master","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200S (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V15.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MV420 SR-B","versions":[{"status":"affected","version":"0","lessThan":"V7.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MV420 SR-B Body","versions":[{"status":"affected","version":"0","lessThan":"V7.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MV420 SR-P","versions":[{"status":"affected","version":"0","lessThan":"V7.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MV420 SR-P Body","versions":[{"status":"affected","version":"0","lessThan":"V7.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MV440 HR","versions":[{"status":"affected","version":"0","lessThan":"V7.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MV440 SR","versions":[{"status":"affected","version":"0","lessThan":"V7.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC MV440 UR","versions":[{"status":"affected","version":"0","lessThan":"V7.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)","versions":[{"status":"affected","version":"All versions < V4.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RF650R","versions":[{"status":"affected","version":"All versions < V3.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RF680R","versions":[{"status":"affected","version":"All versions < V3.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC RF685R","versions":[{"status":"affected","version":"All versions < V3.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.2.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller","versions":[{"status":"affected","version":"All versions < V2.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-200 SMART","versions":[{"status":"affected","version":"All versions < V2.3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V3.X.14","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V6.0.7","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V6.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V7.0.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-410 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V8.2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC TDC CP51M1","versions":[{"status":"affected","version":"0","lessThan":"V1.1.8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC TDC CPU555","versions":[{"status":"affected","version":"0","lessThan":"V1.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Teleservice Adapter IE Advanced","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Teleservice Adapter IE Basic","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Teleservice Adapter IE Standard","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinAC RTX 2010","versions":[{"status":"affected","version":"All versions < V2010 SP3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinAC RTX F 2010","versions":[{"status":"affected","version":"All versions < V2010 SP3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOCODE pro V PROFINET (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.0.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOTION","versions":[{"status":"affected","version":"All versions < V4.5 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.4 HF26"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS DCM w. PN","versions":[{"status":"affected","version":"All versions < V1.4 SP1 HF5"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS DCP w. PN","versions":[{"status":"affected","version":"All versions < V1.2 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G110M w. PN","versions":[{"status":"affected","version":"All versions < V4.7 SP6 HF3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.7 SP6 HF3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G130 V4.7 w. PN","versions":[{"status":"affected","version":"All versions < V4.7 HF27"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G130 V4.8 w. PN","versions":[{"status":"affected","version":"All versions < V4.8 HF4"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G150 V4.7 w. PN","versions":[{"status":"affected","version":"V4.7: All versions < V4.7 HF27"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G150 V4.8 w. PN","versions":[{"status":"affected","version":"All versions < V4.8 HF4"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS GH150 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.7 SP5 HF7"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS GL150 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS GM150 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.7 HF31"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S110 w. PN","versions":[{"status":"affected","version":"All versions < V4.4 SP3 HF5"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.7"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.7 HF27"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.8 HF4"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S150 V4.7 w. PN","versions":[{"status":"affected","version":"All versions < V4.7 HF27"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S150 V4.8 w. PN","versions":[{"status":"affected","version":"All versions < V4.8 HF4"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SL150 V4.7.0 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.7 HF30"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SL150 V4.7.4 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SL150 V4.7.5 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SM120 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS V90 w. PN","versions":[{"status":"affected","version":"All versions < V1.01"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINUMERIK 828D V4.5 and prior","versions":[{"status":"affected","version":"All versions < V4.5 SP6 HF2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINUMERIK 828D V4.7","versions":[{"status":"affected","version":"All versions < V4.7 SP4 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINUMERIK 840D sl V4.5 and prior","versions":[{"status":"affected","version":"All versions < V4.5 SP6 HF2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINUMERIK 840D sl V4.7","versions":[{"status":"affected","version":"All versions < V4.7 SP4 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIRIUS ACT 3SU1 interface module PROFINET","versions":[{"status":"affected","version":"All versions < V1.1.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIRIUS Motor Starter M200D PROFINET","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIRIUS Soft Starter 3RW44 PN","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SITOP PSU8600 PROFINET","versions":[{"status":"affected","version":"All versions < V1.2.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SITOP UPS1600 PROFINET (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.2.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Softnet PROFINET IO for PC-based Windows systems","versions":[{"status":"affected","version":"All versions < V14 SP1"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","baseScore":7.1,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-400","description":"CWE-400: Uncontrolled Resource Consumption","type":"CWE"}]}],"references":[{"name":"1038463","tags":["vdb-entry","x_refsource_SECTRACK"],"url":"http://www.securitytracker.com/id/1038463"},{"name":"98369","tags":["vdb-entry","x_refsource_BID"],"url":"http://www.securityfocus.com/bid/98369"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"},{"tags":["x_refsource_CONFIRM"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"},{"tags":["x_refsource_MISC"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-293562.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-284673.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-546832.html"}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-07-09T13:26:04.237652Z","id":"CVE-2017-2680","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2024-07-09T13:26:15.327Z"}},{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T14:02:07.270Z"},"title":"CVE Program Container","references":[{"name":"1038463","tags":["vdb-entry","x_refsource_SECTRACK","x_transferred"],"url":"http://www.securitytracker.com/id/1038463"},{"name":"98369","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"http://www.securityfocus.com/bid/98369"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-293562.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-284673.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-546832.html","tags":["x_transferred"]}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2017-2680","datePublished":"2017-05-11T01:00:00.000Z","dateReserved":"2016-12-01T00:00:00.000Z","dateUpdated":"2024-09-10T09:33:18.492Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}