{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2017-20236","assignerOrgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","state":"PUBLISHED","assignerShortName":"VulnCheck","dateReserved":"2026-04-03T19:07:31.394Z","datePublished":"2026-04-03T22:54:00.846Z","dateUpdated":"2026-05-25T23:40:57.660Z"},"containers":{"cna":{"providerMetadata":{"orgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","shortName":"VulnCheck","dateUpdated":"2026-05-25T23:40:57.660Z"},"datePublic":"2017-05-08T00:00:00.000Z","title":"ProSoft Technology ICX35-HWC Command Injection via Web Interface","descriptions":[{"lang":"en","value":"ProSoft Technology ICX35-HWC versions 1.3 and prior cellular gateways contain an input validation vulnerability in the web user interface that allows remote attackers to inject and execute system commands by submitting malicious input through unvalidated fields. Attackers can exploit this vulnerability to gain root privileges and execute arbitrary commands on the device through the accessible web interface."}],"affected":[{"vendor":"ProSoft Technology","product":"ICX35-HWC Cellular Gateway","versions":[{"status":"affected","version":"0","versionType":"custom","lessThanOrEqual":"1.3"}],"defaultStatus":"affected"}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-78","description":"Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') (CWE-78)","type":"CWE"}]}],"metrics":[{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV3_1":{"attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH","version":"3.1","baseSeverity":"CRITICAL","baseScore":9.8,"vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"}},{"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}],"cvssV4_0":{"attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","subConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","subIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subAvailabilityImpact":"NONE","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED","version":"4.0","baseSeverity":"CRITICAL","baseScore":9.3,"vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"}}],"source":{"discovery":"EXTERNAL"},"references":[{"url":"https://assets.belden.com/m/1116a05ab702b2ba/original/Security-Bulletin-User-Interface-ProSoft-ICX35-BSECV-2017-10.pdf","tags":["vendor-advisory"]},{"url":"https://www.vulncheck.com/advisories/prosoft-technology-icx35-hwc-command-injection-via-web-interface","tags":["third-party-advisory"]}]},"adp":[{"metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2017-20236","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"total"}],"version":"2.0.3","timestamp":"2026-04-06T17:53:34.782491Z"}}}],"title":"CISA ADP Vulnrichment","providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-04-06T18:02:55.640Z"}}]}}