{"containers":{"cna":{"providerMetadata":{"orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","shortName":"siemens","dateUpdated":"2024-07-09T12:03:53.948Z"},"descriptions":[{"lang":"en","value":"Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually."}],"affected":[{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","versions":[{"status":"affected","version":"All versions < V4.1.1 Patch 05"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200","versions":[{"status":"affected","version":"All versions < V4.5"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P","versions":[{"status":"affected","version":"All versions < V4.5"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC Compact Field Unit","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200AL IM 157-1 PN","versions":[{"status":"affected","version":"0","lessThan":"V1.0.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200M (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN BA","versions":[{"status":"affected","version":"0","lessThan":"V4.0.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200MP IM 155-5 PN ST","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-3 PN HF","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200pro IM 154-4 PN HF","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN BA","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V1.1.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN HS","versions":[{"status":"affected","version":"0","lessThan":"V4.0.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST BA","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET 200SP IM 155-6 PN ST BA","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 4AO U/I 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200ecoPN: IO-Link Master","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC ET200S (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)","versions":[{"status":"affected","version":"All versions < V4.2.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1200 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.2.3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 Software Controller","versions":[{"status":"affected","version":"All versions < V2.0"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-200 SMART","versions":[{"status":"affected","version":"All versions < V2.03.01"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V3.X.16","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V6.0.8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V6.0.6","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"0","lessThan":"V7.0.2","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V8.2.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC TDC CP51M1","versions":[{"status":"affected","version":"0","lessThan":"V1.1.8","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC TDC CPU555","versions":[{"status":"affected","version":"0","lessThan":"V1.1.1","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinAC RTX 2010","versions":[{"status":"affected","version":"All versions < V2010 SP3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC WinAC RTX F 2010","versions":[{"status":"affected","version":"All versions < V2010 SP3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOCODE pro V PROFINET (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V2.1.1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOTION C","versions":[{"status":"affected","version":"All versions < V5.1 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOTION D","versions":[{"status":"affected","version":"All versions < V5.1 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.4 HF26"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOTION P V4.4 and V4.5","versions":[{"status":"affected","version":"All versions < V4.5 HF5"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMOTION P V5","versions":[{"status":"affected","version":"All versions < V5.1 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS DCM w. PN","versions":[{"status":"affected","version":"All versions < V1.4 SP1 HF6"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS DCP w. PN","versions":[{"status":"affected","version":"All versions < V1.2 HF2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G110M w. PN","versions":[{"status":"affected","version":"All versions < V4.7 SP9 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.7 SP9 HF1"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G130 V4.7 w. PN","versions":[{"status":"affected","version":"All versions < V4.7 HF29"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G130 V4.8 w. PN","versions":[{"status":"affected","version":"All versions < V4.8 HF4"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G150 V4.7 w. PN","versions":[{"status":"affected","version":"All versions < V4.7 HF29"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS G150 V4.8 w. PN","versions":[{"status":"affected","version":"All versions < V4.8 HF4"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS GH150 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.7 SP5 HF7"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS GL150 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS GM150 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.7 HF31"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S110 w. PN","versions":[{"status":"affected","version":"All versions < V4.4 SP3 HF6"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.7"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.7 HF29"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)","versions":[{"status":"affected","version":"All versions < V4.8 HF5"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S150 V4.7 w. PN","versions":[{"status":"affected","version":"All versions < V4.7 HF29"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS S150 V4.8 w. PN","versions":[{"status":"affected","version":"All versions < V4.8 HF4"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SL150 V4.7.0 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.7 HF30"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SL150 V4.7.4 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SL150 V4.7.5 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS SM120 V4.7 w. PROFINET","versions":[{"status":"affected","version":"All versions < V4.8 SP2"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINAMICS V90 w. PN","versions":[{"status":"affected","version":"All versions < V1.02"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SINUMERIK 840D sl","versions":[{"status":"affected","version":"All versions < V4.8 SP3"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200MP IM 155-5 PN ST TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.1.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL","versions":[{"status":"affected","version":"0","lessThan":"V4.2.0","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS ET 200SP IM 155-6 PN ST TX RAIL","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIRIUS Soft Starter 3RW44 PN","versions":[{"status":"affected","version":"All versions"}],"defaultStatus":"unknown"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH"}},{"cvssV4_0":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","baseScore":8.7,"baseSeverity":"HIGH"}}],"problemTypes":[{"descriptions":[{"lang":"en","cweId":"CWE-400","description":"CWE-400: Uncontrolled Resource Consumption","type":"CWE"}]}],"references":[{"name":"101964","tags":["vdb-entry","x_refsource_BID"],"url":"https://www.securityfocus.com/bid/101964"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf"},{"tags":["x_refsource_CONFIRM"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-346262.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-546832.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-141614.html"}]},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-05T18:51:06.315Z"},"title":"CVE Program Container","references":[{"name":"101964","tags":["vdb-entry","x_refsource_BID","x_transferred"],"url":"https://www.securityfocus.com/bid/101964"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-346262.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-546832.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-141614.html","tags":["x_transferred"]}]}]},"cveMetadata":{"assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","assignerShortName":"siemens","cveId":"CVE-2017-12741","datePublished":"2017-12-26T04:00:00.000Z","dateReserved":"2017-08-09T00:00:00.000Z","dateUpdated":"2024-08-05T18:51:06.315Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}