{"containers":{"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2015-12-01T00:00:00.000Z","descriptions":[{"lang":"en","value":"Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2015-12-15T04:57:02.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-631"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-625"},{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-634"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-632"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-630"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-633"},{"tags":["x_refsource_MISC"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-635"},{"tags":["x_refsource_CONFIRM"],"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2015-7918","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-631","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-631"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-625","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-625"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-634","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-634"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-632","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-632"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-630","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-630"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-633","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-633"},{"name":"http://www.zerodayinitiative.com/advisories/ZDI-15-635","refsource":"MISC","url":"http://www.zerodayinitiative.com/advisories/ZDI-15-635"},{"name":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01","refsource":"CONFIRM","url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-06T08:06:30.979Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-631"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-625"},{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-634"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-632"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-630"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-633"},{"tags":["x_refsource_MISC","x_transferred"],"url":"http://www.zerodayinitiative.com/advisories/ZDI-15-635"},{"tags":["x_refsource_CONFIRM","x_transferred"],"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2015-7918","datePublished":"2015-12-15T02:00:00.000Z","dateReserved":"2015-10-22T00:00:00.000Z","dateUpdated":"2024-08-06T08:06:30.979Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}