{"containers":{"cna":{"affected":[{"product":"RSLinx Enterprise Software","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"CPR9"},{"status":"affected","version":"CPR9-SR1"},{"status":"affected","version":"CPR9-SR2"},{"status":"affected","version":"CPR9-SR3"},{"status":"affected","version":"CPR9-SR4"},{"status":"affected","version":"CPR9-SR5"},{"status":"affected","version":"CPR9-SR5.1"},{"status":"affected","version":"CPR9-SR6"}]}],"datePublic":"2013-10-07T00:00:00.000Z","descriptions":[{"lang":"en","value":"Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-190","description":"Integer overflow CWE-190","lang":"en","type":"CWE"}]}],"providerMetadata":{"dateUpdated":"2019-03-26T16:44:28.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","shortName":"icscert"},"references":[{"tags":["x_refsource_MISC"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2013-2807","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"RSLinx Enterprise Software","version":{"version_data":[{"version_value":"CPR9"},{"version_value":"CPR9-SR1"},{"version_value":"CPR9-SR2"},{"version_value":"CPR9-SR3"},{"version_value":"CPR9-SR4"},{"version_value":"CPR9-SR5"},{"version_value":"CPR9-SR5.1"},{"version_value":"CPR9-SR6"}]}}]},"vendor_name":"Rockwell Automation"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599"}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Integer overflow CWE-190"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-06T15:52:20.544Z"},"title":"CVE Program Container","references":[{"tags":["x_refsource_MISC","x_transferred"],"url":"https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02"}]}]},"cveMetadata":{"assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","assignerShortName":"icscert","cveId":"CVE-2013-2807","datePublished":"2019-03-26T16:35:16.000Z","dateReserved":"2013-04-11T00:00:00.000Z","dateUpdated":"2024-08-06T15:52:20.544Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}