{"containers":{"cna":{"affected":[{"product":"n/a","vendor":"n/a","versions":[{"status":"affected","version":"n/a"}]}],"datePublic":"2006-11-08T00:00:00.000Z","descriptions":[{"lang":"en","value":"radexecd.exe in HP OpenView Client Configuraton Manager (CCM) does not require authentication before executing commands in the installation directory, which allows remote attackers to cause a denial of service (reboot) by calling radbootw.exe or create arbitrary files by calling radcrecv."}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"dateUpdated":"2018-10-17T20:57:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre"},"references":[{"name":"20061108 TSRT-06-13: HP OpenView Client Configuration Manager Device Code Execution Vulnerability","tags":["mailing-list","x_refsource_BUGTRAQ"],"url":"http://www.securityfocus.com/archive/1/450942/100/0/threaded"},{"name":"22780","tags":["third-party-advisory","x_refsource_SECUNIA"],"url":"http://secunia.com/advisories/22780"},{"name":"HPSBMA02167","tags":["vendor-advisory","x_refsource_HP"],"url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c00795552"},{"name":"1842","tags":["third-party-advisory","x_refsource_SREASON"],"url":"http://securityreason.com/securityalert/1842"},{"name":"ADV-2006-4410","tags":["vdb-entry","x_refsource_VUPEN"],"url":"http://www.vupen.com/english/advisories/2006/4410"},{"name":"hp-openview-radianotify-dos(30138)","tags":["vdb-entry","x_refsource_XF"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/30138"},{"name":"SSRT061262","tags":["vendor-advisory","x_refsource_HP"],"url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c00795552"},{"name":"1017197","tags":["vdb-entry","x_refsource_SECTRACK"],"url":"http://securitytracker.com/id?1017197"}],"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2006-5782","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"radexecd.exe in HP OpenView Client Configuraton Manager (CCM) does not require authentication before executing commands in the installation directory, which allows remote attackers to cause a denial of service (reboot) by calling radbootw.exe or create arbitrary files by calling radcrecv."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"20061108 TSRT-06-13: HP OpenView Client Configuration Manager Device Code Execution Vulnerability","refsource":"BUGTRAQ","url":"http://www.securityfocus.com/archive/1/450942/100/0/threaded"},{"name":"22780","refsource":"SECUNIA","url":"http://secunia.com/advisories/22780"},{"name":"HPSBMA02167","refsource":"HP","url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c00795552"},{"name":"1842","refsource":"SREASON","url":"http://securityreason.com/securityalert/1842"},{"name":"ADV-2006-4410","refsource":"VUPEN","url":"http://www.vupen.com/english/advisories/2006/4410"},{"name":"hp-openview-radianotify-dos(30138)","refsource":"XF","url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/30138"},{"name":"SSRT061262","refsource":"HP","url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c00795552"},{"name":"1017197","refsource":"SECTRACK","url":"http://securitytracker.com/id?1017197"}]}}},"adp":[{"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2024-08-07T20:04:55.573Z"},"title":"CVE Program Container","references":[{"name":"20061108 TSRT-06-13: HP OpenView Client Configuration Manager Device Code Execution Vulnerability","tags":["mailing-list","x_refsource_BUGTRAQ","x_transferred"],"url":"http://www.securityfocus.com/archive/1/450942/100/0/threaded"},{"name":"22780","tags":["third-party-advisory","x_refsource_SECUNIA","x_transferred"],"url":"http://secunia.com/advisories/22780"},{"name":"HPSBMA02167","tags":["vendor-advisory","x_refsource_HP","x_transferred"],"url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c00795552"},{"name":"1842","tags":["third-party-advisory","x_refsource_SREASON","x_transferred"],"url":"http://securityreason.com/securityalert/1842"},{"name":"ADV-2006-4410","tags":["vdb-entry","x_refsource_VUPEN","x_transferred"],"url":"http://www.vupen.com/english/advisories/2006/4410"},{"name":"hp-openview-radianotify-dos(30138)","tags":["vdb-entry","x_refsource_XF","x_transferred"],"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/30138"},{"name":"SSRT061262","tags":["vendor-advisory","x_refsource_HP","x_transferred"],"url":"http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c00795552"},{"name":"1017197","tags":["vdb-entry","x_refsource_SECTRACK","x_transferred"],"url":"http://securitytracker.com/id?1017197"}]}]},"cveMetadata":{"assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","assignerShortName":"mitre","cveId":"CVE-2006-5782","datePublished":"2006-11-09T00:00:00.000Z","dateReserved":"2006-11-07T00:00:00.000Z","dateUpdated":"2024-08-07T20:04:55.573Z","state":"PUBLISHED"},"dataType":"CVE_RECORD","dataVersion":"5.1"}